A 1-Phase input is connected to terminals L1/L2 or L2/L3 (do not connect a 1-Phase
input between L1/L3), while a 3-Phase input is connected to L1/L2/L3 (a connection to
neutral is not utilized with 3-Phase input). The connector has compression terminals
with female contacts. A ground connection must always be made to the utility earth
protection ground using the AC Input connector pin or rear panel safety-ground stud.
Figure 2-6 shows the AC input connector wiring for 3-phase and 1-Phase connections.
Name
Type
Function
AC INPUT L1
AC Input
Line-1 input from utility AC mains;
For 1-Phase input, connect lines to terminals L1 and L2, or L2 and
L3; or L1 and L3
AC INPUT L2
AC Input
Line-2 input from utility AC mains.
For 1-Phase input, connect lines to terminals L1 and L2, or L2 and
L3; or L1 and L3
AC INPUT L3
AC Input
Line-3 input from utility AC mains;
For 1-Phase input, connect lines to terminals L1 and L2, or L2 and
L3; or L1 and L3
GND
Safety
Ground
Safety-Ground connection from utility earth protection-ground.
Table 2-4: AC Input Connector Pinout and Safety-Ground
Connector
Type
AC Input
Chassis connector header: Phoenix P/N 1708514; 4-position, compression
terminals;
Mating connector: Phoenix P/N 1709173; compression terminals; housing retained
to header with screws;
Wire stripping length: 10 mm (0.39”);
Tightening torque: 0.7 Nm, min (6.1 lb-in) to 0.8 Nm, max (7 lb-in);
Wire cross section: 0.2 mm
2
, min (24 AWG) to 6 mm
2
, max (10 AWG).
Refer to Phoenix P/N 1709173 manufacturer datasheet for the complete
specifications of the Mating Connector.
Safety-Ground
Use the GND pin (G) provided in the input AC connector, or the Stud provided in the
rear panel for Safety-Ground Connection. For using the rear panel M4-0.7 x 7 stud,
use nut tightening torque is 1.1 Nm (10 lb-in) max.
Table 2-5: AC Input Connector Type
CAUTION!
To prevent damage to the AC input mating connector, follow torque specifications,
and, if a wire ferrule is used, ensure that it is properly sized and that it has been
crimped with the appropriate ferrule crimping tool.