Rate Limiters
The section describes how to configure the switch’s ACL Rate Limiter parameters. The Rate Limiter ID
ranges from 1 to 16 and the rate is set in pps or kbps.
To configure ACL Rate Limiter via the web interface:
1. Navigate to
Configuration
>
ACL
>
Rate Limiter
.
2. Specify the rate ranging from 0 to 3276700.
3. Scroll to set the Unit to pps or kbps.
4. Click
Apply
or click
Reset
to revert to previously saved values.
0.
Figure 29:
ACL Rate Limiter Configuration
Parameter
Description
Rate Limiter ID
The rate limiter ID for the settings.
Rate
The values are: 0-3276700 in pps or 0, 100, 200, 300, ..., 1000000 in kbps.
Unit
Specify the rate unit. The values are:
pps:
packets per second.
kbps:
Kbits per second.