338
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
17
:FUNCtion<m> Commands
:FUNCtion<m>[:FFT]:SP
AN <span> (see
page 349
)
:FUNCtion<m>[:FFT]:SP
AN? (see
page 349
)
<span> ::= the current frequency
span in NR3 format.
Legal values are 1 Hz to 100 GHz.
<m> ::= 1-4 in NR1 format
:FUNCtion<m>[:FFT]:VT
YPe <units> (see
page 350
)
:FUNCtion<m>[:FFT]:VT
YPe? (see
page 350
)
<units> ::= {DECibel | VRMS}
<m> ::= 1-4 in NR1 format
:FUNCtion<m>[:FFT]:WI
NDow <window> (see
page 351
)
:FUNCtion<m>[:FFT]:WI
NDow? (see
page 351
)
<window> ::= {RECTangular |
HANNing | FLATtop | BHARris}
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:FREQuenc
y:HIGHpass <3dB_freq>
(see
page 352
)
:FUNCtion<m>:FREQuenc
y:HIGHpass? (see
page 352
)
<3dB_freq> ::= 3dB cutoff
frequency value in NR3 format
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:FREQuenc
y:LOWPass <3dB_freq>
(see
page 353
)
:FUNCtion<m>:FREQuenc
y:LOWPass? (see
page 353
)
<3dB_freq> ::= 3dB cutoff
frequency value in NR3 format
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:INTegrat
e:IOFFset
<input_offset> (see
page 354
)
:FUNCtion<m>:INTegrat
e:IOFFset? (see
page 354
)
<input_offset> ::= DC offset
correction in NR3 format.
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:LINear:G
AIN <value> (see
page 355
)
:FUNCtion<m>:LINear:G
AIN? (see
page 355
)
<value> ::= 'A' in Ax + B, value
in NR3 format
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:LINear:O
FFSet <value> (see
page 356
)
:FUNCtion<m>:LINear:O
FFSet? (see
page 356
)
<value> ::= 'B' in Ax + B, value
in NR3 format
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:OFFSet
<offset> (see
page 357
)
:FUNCtion<m>:OFFSet?
(see
page 357
)
<offset> ::= the value at center
screen in NR3 format.
The range of legal values is
+/-10 times the current
sensitivity of the selected
function.
<m> ::= 1-4 in NR1 format
:FUNCtion<m>:OPERatio
n <operation> (see
page 358
)
:FUNCtion<m>:OPERatio
n? (see
page 359
)
<operation> ::= {ADD | SUBTract |
MULTiply | DIVide | INTegrate |
DIFF | FFT | SQRT | MAGNify |
ABSolute | SQUare | LN | LOG |
EXP | TEN | LOWPass | HIGHpass |
AVERage | LINear | TRENd |
BTIMing | BSTate}
<m> ::= 1-4 in NR1 format
Table 92 :FUNCtion<m> Commands Summary (continued)
Command
Query
Options and Query Returns
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...