:WGEN<w>:MODulation:FM:DEViation
(see
page 1208
)
Command Syntax
:WGEN<w>:MODulation:FM:DEViation <frequency>
<w> ::= 1 in NR1 format
<frequency> ::= frequency deviation in Hz in NR3 format
The :WGEN<w>:MODulation:FM:DEViation command specifies the frequency
deviation from the original carrier signal frequency.
When the modulating signal is at its maximum amplitude, the output
frequency is the carrier signal frequency plus the deviation amount, and
when the modulating signal is at its minimum amplitude, the output
frequency is the carrier signal frequency minus the deviation amount.
The frequency deviation cannot be greater than the original carrier signal
frequency.
Also, the sum of the original carrier signal frequency and the frequency
deviation must be less than or equal to the maximum frequency for the
selected waveform generator function plus 100 kHz.
Query Syntax
:WGEN<w>:MODulation:FM:DEViation?
The :WGEN<w>:MODulation:FM:DEViation? query returns the frequency
deviation setting.
Return Format
<frequency><NL>
<frequency> ::= frequency deviation in Hz in NR3 format
See Also
•
":WGEN<w>:MODulation:AM:DEPTh"
on page 1073
•
":WGEN<w>:MODulation:AM:FREQuency"
on page 1074
•
":WGEN<w>:MODulation:FM:FREQuency"
on page 1076
•
":WGEN<w>:MODulation:FSKey:FREQuency"
on page 1077
•
":WGEN<w>:MODulation:FSKey:RATE"
on page 1078
•
":WGEN<w>:MODulation:FUNCtion"
on page 1079
•
":WGEN<w>:MODulation:FUNCtion:RAMP:SYMMetry"
on page 1080
•
":WGEN<w>:MODulation:STATe"
on page 1082
•
":WGEN<w>:MODulation:TYPE"
on page 1083
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...