148
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
4
Commands Quick Reference
Table 58 :TRIGger:RUNT Commands Summary
Command
Query
Options and Query Returns
:TRIGger:RUNT:POLarit
y <polarity> (see
page 987
)
:TRIGger:RUNT:POLarit
y? (see
page 987
)
<polarity> ::= {POSitive |
NEGative | EITHer}
:TRIGger:RUNT:QUALifi
er <qualifier> (see
page 988
)
:TRIGger:RUNT:QUALifi
er? (see
page 988
)
<qualifier> ::= {GREaterthan |
LESSthan | NONE}
:TRIGger:RUNT:SOURce
<source> (see
page 989
)
:TRIGger:RUNT:SOURce?
(see
page 989
)
<source> ::= CHANnel<n>
<n> ::= 1 to (# analog channels)
in NR1 format
:TRIGger:RUNT:TIME
<time>[suffix] (see
page 990
)
:TRIGger:RUNT:TIME?
(see
page 990
)
<time> ::= floating-point number
in NR3 format
[suffix] ::= {s | ms | us | ns |
ps}
Table 59 :TRIGger:SHOLd Commands Summary
Command
Query
Options and Query Returns
:TRIGger:SHOLd:SLOPe
<slope> (see
page 992
)
:TRIGger:SHOLd:SLOPe?
(see
page 992
)
<slope> ::= {NEGative | POSitive}
:TRIGger:SHOLd:SOURce
:CLOCk <source> (see
page 993
)
:TRIGger:SHOLd:SOURce
:CLOCk? (see
page 993
)
<source> ::= {CHANnel<n> |
DIGital<d>}
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:TRIGger:SHOLd:SOURce
:DATA <source> (see
page 994
)
:TRIGger:SHOLd:SOURce
:DATA? (see
page 994
)
<source> ::= {CHANnel<n> |
DIGital<d>}
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
:TRIGger:SHOLd:TIME:H
OLD <time>[suffix]
(see
page 995
)
:TRIGger:SHOLd:TIME:H
OLD? (see
page 995
)
<time> ::= floating-point number
in NR3 format
[suffix] ::= {s | ms | us | ns |
ps}
:TRIGger:SHOLd:TIME:S
ETup <time>[suffix]
(see
page 996
)
:TRIGger:SHOLd:TIME:S
ETup? (see
page 996
)
<time> ::= floating-point number
in NR3 format
[suffix] ::= {s | ms | us | ns |
ps}
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...