:WGEN<w> Commands
PULSe
Use these commands to set the pulse signal
parameters:
•
":WGEN<w>:FREQuency"
on page 1066
•
":WGEN<w>:PERiod"
on page 1088
•
":WGEN<w>:VOLTage"
on page 1094
•
":WGEN<w>:VOLTage:OFFSet"
on page 1097
•
":WGEN<w>:VOLTage:HIGH"
on page 1095
•
":WGEN<w>:VOLTage:LOW"
on page 1096
•
":WGEN<w>:FUNCtion:PULSe:WIDTh"
on
page 1070
The pulse width can be adjusted from 20 ns to the
period minus 20 ns.
100 mHz to
10 MHz.
20 mVpp to
10 Vpp
±5.00 V
DC
Use this command to set the DC level:
•
":WGEN<w>:VOLTage:OFFSet"
on page 1097
n/a
n/a
±10.00 V
NOISe
Use these commands to set the noise signal
parameters:
•
":WGEN<w>:VOLTage"
on page 1094
•
":WGEN<w>:VOLTage:OFFSet"
on page 1097
•
":WGEN<w>:VOLTage:HIGH"
on page 1095
•
":WGEN<w>:VOLTage:LOW"
on page 1096
n/a
20 mVpp to
10 Vpp
±5.00 V
SINC
Use these commands to set the sine cardinal
signal parameters:
•
":WGEN<w>:FREQuency"
on page 1066
•
":WGEN<w>:PERiod"
on page 1088
•
":WGEN<w>:VOLTage"
on page 1094
•
":WGEN<w>:VOLTage:OFFSet"
on page 1097
100 mHz to
1 MHz
20 mVpp to
9 Vpp
±2.50 V
EXPRise
Use these commands to set the exponential rise
signal parameters:
•
":WGEN<w>:FREQuency"
on page 1066
•
":WGEN<w>:PERiod"
on page 1088
•
":WGEN<w>:VOLTage"
on page 1094
•
":WGEN<w>:VOLTage:OFFSet"
on page 1097
•
":WGEN<w>:VOLTage:HIGH"
on page 1095
•
":WGEN<w>:VOLTage:LOW"
on page 1096
100 mHz to
5 MHz
20 mVpp to
10 Vpp
±5.00 V
EXPFall
Use these commands to set the exponential fall
signal parameters:
•
":WGEN<w>:FREQuency"
on page 1066
•
":WGEN<w>:PERiod"
on page 1088
•
":WGEN<w>:VOLTage"
on page 1094
•
":WGEN<w>:VOLTage:OFFSet"
on page 1097
•
":WGEN<w>:VOLTage:HIGH"
on page 1095
•
":WGEN<w>:VOLTage:LOW"
on page 1096
100 mHz to
5 MHz
20 mVpp to
10 Vpp
±5.00 V
Waveform
Type
Characteristics
Frequency
Range
Max.
Amplitude
2
(High-Z)
1
Offset
2
(High-Z)
1
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...