Commands Quick Reference
4
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
129
:SBUS<n>:USB:TRIGger:
DATA <string> (see
page 803
)
:SBUS<n>:USB:TRIGger:
DATA? (see
page 803
)
<string> ::= "nnnn..." where n
::= {0 | 1 | X}
<string> ::= "0xn..." where n ::=
{0,..,9 | A,..,F | X | $}
:SBUS<n>:USB:TRIGger:
DATA:LENGth <value>
(see
page 804
)
:SBUS<n>:USB:TRIGger:
DATA:LENGth? (see
page 804
)
<length> ::= data length between
1-20
:SBUS<n>:USB:TRIGger:
ENDPoint <string>
(see
page 805
)
:SBUS<n>:USB:TRIGger:
ENDPoint? (see
page 805
)
<string> ::= "nnnn" where n ::=
{0 | 1 | X}
<string> ::= "0xn" where n ::=
{0,..,9 | A,..,F | X | $}
:SBUS<n>:USB:TRIGger:
ET <string> (see
page 806
)
:SBUS<n>:USB:TRIGger:
ET? (see
page 806
)
<string> ::= "nn" where n ::= {0
| 1 | X}
<string> ::= "0xn" where n ::= {0
| 1 | 2 | 3 | X | $}
:SBUS<n>:USB:TRIGger:
FRAMe <string> (see
page 807
)
:SBUS<n>:USB:TRIGger:
FRAMe? (see
page 807
)
<string> ::= "nnnnnnnnnnn" where
n ::= {0 | 1 | X}
<string> ::= "0xnnn" where n ::=
{0,..,9 | A,..,F | X | $}
:SBUS<n>:USB:TRIGger:
HADDress <string>
(see
page 808
)
:SBUS<n>:USB:TRIGger:
HADDress? (see
page 808
)
<string> ::= "nnnnnnn" where n
::= {0 | 1 | X}
<string> ::= "0xnn" where n ::=
{0,..,9 | A,..,F | X | $}
:SBUS<n>:USB:TRIGger:
PCHeck <string> (see
page 809
)
:SBUS<n>:USB:TRIGger:
PCHeck? (see
page 809
)
<string> ::= "nnnn" where n ::=
{0 | 1 | X}
<string> ::= "0xn" where n ::=
{0,..,9 | A,..,F | X | $}
:SBUS<n>:USB:TRIGger:
PID:DATA <pid> (see
page 810
)
:SBUS<n>:USB:TRIGger:
PID:DATA? (see
page 810
)
<pid> ::= {DATA0 | DATA1 | DATA2
| MDATa}
:SBUS<n>:USB:TRIGger:
PID:HANDshake <pid>
(see
page 811
)
:SBUS<n>:USB:TRIGger:
PID:HANDshake? (see
page 811
)
<pid> ::= {ACK | NAK | STALL |
NYET}
:SBUS<n>:USB:TRIGger:
PID:SPECial <pid>
(see
page 812
)
:SBUS<n>:USB:TRIGger:
PID:SPECial? (see
page 812
)
<pid> ::= {PING | PRE | ERR |
SPLit}
:SBUS<n>:USB:TRIGger:
PID:TOKen <pid> (see
page 813
)
:SBUS<n>:USB:TRIGger:
PID:TOKen? (see
page 813
)
<pid> ::= {OUT | IN | SETup |
SOF}
Table 33 :SBUS<n>:USB Commands Summary (continued)
Command
Query
Options and Query Returns
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...