:SBUS<n> Commands
28
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
743
:SBUS<n>:LIN:TRIGger:PATTern:DATA
(see
page 1208
)
Command Syntax
:SBUS<n>:LIN:TRIGger:PATTern:DATA <string>
<string> ::= "n" where n ::= 32-bit integer in unsigned decimal when
<base> = DECimal
<string> ::= "nn...n" where n ::= {0 | 1 | X | $} when
<base> = BINary
<string> ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X | $} when
<base> = HEX
The :SBUS<n>:LIN:TRIGger:PATTern:DATA command specifies the LIN
trigger data pattern searched for in each LIN data field.
Set a <string> bit to "0" or "1" to set the corresponding bit in the data
pattern to low or high, respectively.
Set a <string> bit to "X" to ignore (mask off) that bit in the data pattern.
Use the "$" character to indicate that the value of the corresponding bit
will not be changed (the existing bit value is used).
When <base> = DECimal, the "X" and "$" characters cannot be entered.
When queried, the "$" character is returned when any bits in the pattern
have the value of "X" and <base> = DECimal. When any bits in a given
nibble have the value of "X" and <base> = HEX, the "$" character is
returned for the corresponding nibble.
Query Syntax
:SBUS<n>:LIN:TRIGger:PATTern:DATA?
The :SBUS<n>:LIN:TRIGger:PATTern:DATA? query returns the currently
specified LIN trigger data pattern.
Return Format
<string><NL>
N O T E
<base> is specified with the :SBUS<n>:LIN:TRIGger:PATTern:FORMat command. The
default <base> is BINary.
N O T E
The length of the trigger data value is determined by the
:SBUS<n>:LIN:TRIGger:PATTern:DATA:LENGth command.
N O T E
If more bits are sent for <string> than the specified trigger pattern data length, the most
significant bits will be truncated. If the data length size is changed after the <string> is
programmed, the added or deleted bits will be added to or deleted from the least significant
bits.
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...