274
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
10
:CHANnel<n> Commands
:CHANnel<n>:PROBe:HEAD[:TYPE]
(see
page 1208
)
Command Syntax
:CHANnel<n>:PROBe:HEAD[:TYPE] <head_param>
<head_param> ::= {SEND0 | SEND6 | SEND12 | SEND20 | DIFF0 | DIFF6
| DIFF12 | DIFF20 | NONE}
<n> ::= {1 | 2 | 3 | 4}
The :CHANnel<n>:PROBe:HEAD[:TYPE] command sets an analog channel
probe head type and dB value. You can choose from:
•
SEND0 — Single- ended, 0dB.
•
SEND6 — Single- ended, 6dB.
•
SEND12 — Single- ended, 12dB.
•
SEND20 — Single- ended, 20dB.
•
DIFF0 — Differential, 0dB.
•
DIFF6 — Differential, 6dB.
•
DIFF12 — Differential, 12dB.
•
DIFF20 — Differential, 20dB.
Query Syntax
:CHANnel<n>:PROBe:HEAD[:TYPE]?
The :CHANnel<n>:PROBe:HEAD[:TYPE]? query returns the current probe
head type setting for the selected channel.
Return Format
<head_param><NL>
<head_param> ::= {SEND0 | SEND6 | SEND12 | SEND20 | DIFF0 | DIFF6
| DIFF12 | DIFF20 | NONE}
See Also
•
"Introduction to :CHANnel<n> Commands"
on page 264
•
":CHANnel<n>:PROBe"
on page 273
•
":CHANnel<n>:PROBe:ID"
on page 275
•
":CHANnel<n>:PROBe:SKEW"
on page 276
•
":CHANnel<n>:PROBe:STYPe"
on page 277
N O T E
This command is valid only for the 113xA Series probes.
Summary of Contents for InfiniiVision 4000 X-Series
Page 1: ...s1 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 32: ...32 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide ...
Page 52: ...52 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 2 Setting Up ...
Page 66: ...66 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 3 Getting Started ...
Page 242: ...242 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 7 ACQuire Commands ...
Page 252: ...252 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 8 BUS n Commands ...
Page 300: ...300 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 12 DEMO Commands ...
Page 330: ...330 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 15 DVM Commands ...
Page 386: ...386 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 18 HARDcopy Commands ...
Page 484: ...484 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 21 MEASure Commands ...
Page 1098: ...1098 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 34 WGEN w Commands ...
Page 1174: ...1174 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide 37 Error Messages ...
Page 1352: ...1352 Agilent InfiniiVision 4000 X Series Oscilloscopes Programmer s Guide Index ...