Power Quality Analyzer Model 8335
19
Current Sensor
(excluding AmpFlex
®
& MiniFlex
®
)
Nominal RMS current
(A
nom
) [A]
SR clamp
1000
MR clamp
1000
MN93 clamp
200
SL261 clamp (10mV/A)
100
SL261 clamp (100mV/A)
10
MN193 clamp (100A)
100
MN193 clamp (5A)
5
5 A adapter
5
3.2 Electrical Specifications
Sampling Frequency (256 samples per cycle):
12.8kHz samples/sec per channel @ 50Hz
15.36kHz samples/sec per channel @ 60Hz
Waveforms:
Displays voltages and currents
Screen Captures:
50 max
Transients:
Detection and recording of transients (up to 210)
Inrush Current:
Detection and recording of Inrush current (1 max)
Memory:
2GB with date and time programming
Alarm Function:
10,000 alarms max
3.2.1 Voltage Inputs
Range for use:
0 to 1000 Vrms AC+DC phase-to-neutral and neutral-to-earth
0 to 2000 Vrms AC+DC phase-to-phase
(on condition of compliance with 1000 Vrms with respect to earth in CAT III)
Input Impedance:
969 k
W
(between phase and neutral and neutral and earth)
Admissible Overload:
1200 Vrms constant
2000 Vrms for one second
3.2.2 Current Inputs
Operating Range:
0 to 1V
Input Impedance:
1M
W
for current probe circuit
12.4k
W
for AmpFlex
®
and MiniFlex
®
circuit
Overload:
1.7V
Shop for AEMC products online at:
1.877.766.5412
www.
PowerMeterStore
.ca