54
Power Quality Analyzer Model 8335
5.1.2 Inrush Current Mode
The
mode is used to capture (record) inrush currents and to view and delete
the recordings. In capture display mode, two sub-menus
RMS
and
PEAK
are
available. Only a single current inrush capture is kept in memory.
NOTE:
When Inrush Current mode is selected the display screen will depend on
the following conditions:
if …
then …
no capture has been made
the
Capture Schedule
screen is displayed
captures have been made
the
Capture Parameters
screen is displayed
5.1.2.1 Programming a Capture
To program the capture of an inrush current, proceed as follows:
1.
Select the sub-menu by pressing the icon’s yellow button. The
Capture
Schedule
screen is displayed.
5
6
7
1
2
3
4
Figure 5-5
Item
Function
1
Reminder of the mode used
2
Display of sub-mode used
3
Current date and time
4
Battery charge level
5
Displays the parameters of the capture
6
Programs the capture
7
OK:
confirms programming of a capture
: deletes a capture (this icon is displayed if a capture has been made)
Shop for AEMC products online at:
1.877.766.5412
www.
PowerMeterStore
.ca