– 128 –
Device Programming
This menu is used to program keypads, receivers and relay modules.
From Data Field Programming mode, press #93 to display "ZONE PROG?".
Press 0 repeatedly to display "DEVICE PROG?".
DEVICE PROG?
1=YES 0=NO
Press 1 to enter DEVICE PROGRAMMING mode.
DEVICE ADDRESS
01-31, 00=QUIT
The device address identifies the device to the
control. Enter the 2-digit device address number to
match the device's physical address setting (01-30).
Press
✴
to accept entry.
Note: Device Address 04 must be used for the 4285
Voice Module, if one is utilized. If not, it can be used
for another device type.
DEVICE TYPE
Select the type of addressable device as follows:
0 = device not used
1 = alpha keypad (6139/6139R)
3 = RF receiver (4281/5881)
4 = output relay module (4204)
5 = voice (VIP) module (4285)
Press
✴
to accept entry.
SUPERVISED CF?
If type device type 4 (Relay Module) is selected, this
prompt will appear. Enter 1 if the unit is a 4204CF.
If not, enter 0. If 1 is entered, only relay 1 (Output A)
and relay 3 (Output B) on each module are able to
be programmed for functions. This module is usually
used to add two additional supervised bell outputs to
the system.
Press
✴
to continue.
CONSOLE PART.
If device type 1 (Alpha Keypad) is selected, this
prompt will appear. Enter the addressable device's
default partition number (01 to maximum number of
partitions programmed for system in field 2*00). This
is the primary partition for which the device is
intended to be used. Enter "9" to make this keypad a
"Master" keypad for the system. Press
✴
to accept
entry.
RF EXPANDER
HOUSE ID XX
If device type 3 (RF Receiver) is selected, this
prompt will appear. Enter the 2-digit House ID (00-
31). This is required for 5700 series systems only,
or if using a wireless keypad (5827/5827BD) with a
5800 series system.
MODULE PART.
If device type 5 (VIP module) is selected, this prompt
will appear. Enter the partition number 1-8 in which
the module is located. Press
✴
to accept entry.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...