– 49 –
Do not install batteries in wireless transmitters until ready to learn, as will be
indicated under
Programming the RF Transmitters
later in this section.. After
learning, batteries need not be removed.
Compatible 5800 Series Transmitters
Model
Product
Learn As
Description
Input Type
5801
Wireless Panic
UR or RF
• Has four pushbuttons, each with a
Transmitter
unique input (loop) code.
• Programmable responses (e.g.,
Panic, Arm–Stay, Arm–Away,
Disarm, etc.
• For arming/disarming functions,
button must be assigned to a user
code when "adding a user."
5802 Pendant
BR
Only
• Has single pushbutton.
(Personal Emergency
• Usually be programmed for
Transmitter)
response type of 24Hr. Audible or
24 Hr. Silent (other zone
5802CP
Belt Clip
responses are possible).
(Personal Emergency
• Contains a non-replaceable
Transmitter)
battery. At the end of the battery's
life, the entire unit must be
replaced.
• If using for arming/disarming, the
button must be assigned to a user
code when "adding a user."
5802MN
Miniature
UR or RF
• Has single pushbutton
(Personal Emergency
• Usually programmed for a
Transmitter)
response type of 24 Hr. Audible or
24 Hr. Silent (other zone responses
are possible.
• If using for arming/disarming, the
button must be assigned to a user
code when "adding a user."
• Contains a replaceable battery.
5804 Wireless
Key
BR
Only
• Has four pushbuttons, each with
Transmitter
a unique input (loop) code.
• Programmable responses (e.g.,
Arm–Stay, Arm–Away, Disarm,
etc.).
• Contains a replaceable battery.
• If using for arming/disarming, the
button must be assigned to a user
code when "adding a user."
5806/5807 Wireless Photoelectric
RF
• One piece smoke detectors with
5808
Smoke Detectors
built in transmitter.
• 5806 and 5807 UL Listed for
residential fire usage only. 5808 UL
commercial fire listing pending.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...