119 –
Input S/N:L
Axxx -xxxx:L
If 1 was entered at the Learn S/N? prompt, this
screen will appear. The device's serial number can
be automatically learned by faulting the device at
least twice (two consecutive transmissions must be
received by the panel). The keypad will beep twice
after the first transmission, and three times after the
second.
If the serial number is printed on the wireless device,
it may be entered manually rather than learned. The
loop number you want to use for this zone must also
be entered.
010 PROG AS RF:2
A000-5372:2
A summary screen will appear if the serial number
was successfully learned. Press
✴
to continue.
ZN ZT P RC B IN:L
10 03 1 3 1 RF:2
A summary screen for the zone will appear showing
the zone number, zone type (ZT), partition
assignment (P), report code (RC), bell/aux relay
assignment for zone (B), and input device type
(IN:L). Press
✴
to continue. The "Enter Zone No".
prompt will appear again.
Report Code Programming
All report codes are entered using #93 menu mode programming, either through
Report Code Programming, or through the Zone Programming mode while
entering other zone information. In the Vista-100, reports are divided into six
categories. These categories represent the main menu options found in the
Report Code Programming mode. Reports and the categories in which they are
found are as follows:
ALARM CODES
RESTR, SUPV. CODES
SYSTEM GROUP #1
(for groups of 16 zones)
Zone Alarm Reports
Alarm Restore
Closing (arm away)
Trouble
Opening (disarm)
Trouble Restore
System Low Battery
Bypass
Low Battery Restore
Bypass Restore
AC Loss
AC Restore
Periodic Test
Power
Cancel
Program Tamper
SYSTEM GROUP #2
SYSTEM GROUP #3
SYSTEM GROUP #4
Arm Stay
Early Open
Fire Walk Test Start
Time Set, Log Reset
Early Close
Fire Walk Test End
Log 50%, 90% Full
Late Open
Off-Normal
Event Log Overflow
Late Close
Exit Error by Zone
Failed to Open
Exit Error by User
Failed to Close
Recent Close
Auto-Arm Failed
Schedule Change
The programming sequence that follows assumes that you will be entering all
reports for the system at one time. In actuality, you may skip from one main
menu option to another by pressing 0(N) to each main menu option. Main menu
options are highlighted in bold text.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...