– 144 –
Time-Driven Event Programming
The following schedules can be used to activate outputs, bypass zones,
arm/disarm the system, etc. based on a time schedule. Up to 20 events can be
programmed for the system. Time windows must first be defined in order to be
used to trigger events.
If using Time Driven Events to control relays, the following menu items
must first be programmed using #93 Menu Mode - Relay Programming:
• Enter Relay No. (reference identification number)
• Relay Group (if applicable)
• Restriction
• Relay Type (4204 or none)
• ECP address and specific Relay No. if 4204 relays
After entering Scheduling Menu Mode, press 0 until the Timed Events ? prompt
appears.
Timed Events ?
1 Yes 0 = No 0
Enter 1 to program timed events using relay outputs.
TIMED EVENT # ?
01-20, 00=Quit 01
Enter the timed event number to be programmed (01-20)
and press the
✴
key. The system will then prompt the
user to enter the desired action to be taken.
Enter 00 at the TIMED EVENT prompt to quit the timed
event menus and display the Quit ? prompt.
Enter 0 at the Quit ? prompt to
return to the main menu choices
and continue programming. Enter
1 to quit Scheduling Menu Mode.
Quit ?
1 = YES 0 = NO 0
01 ACTION ?
none 00
Enter the action code for the desired action for this event
number from the list at the left. This could be an output
command, an arming command, or any other time-driven
event. Press
✴
to accept the entry and display the
appropriate action specifier prompt as follows on the
next page.
Action Codes:
01=relay On
02=Relay Off
03=Relay Close for 2 seconds
04=Relay Close XX minutes
05=Relay Close YY seconds
Actions 01-05
Enter the relay number and press
✴
to accept entry. The Time
Window ? prompt appears.
01 RELAY # ?
00
06=Relay Group On
07=Relay Group Off
08=Relay Group Close for 2 seconds
09=Relay Group Close XX minutes
10=Relay Group Close YY seconds
Actions 06-10
Enter the relay group number and
press
✴
to accept entry. The
Time Window ? prompt appears.
01 RELAY GRP # ?
00
20=Arm-Stay
21=Arm Away
22=Disarm
23=Force Arm Stay
24=Force Arm Away
40=Enable Open Window by part
41=Enable Close Window by part
Actions 21-24 and 40-41
Enter the partition to which the
action applies. Enter 0 to select
all partitions. Enter a partition
number again to deselect it. Press
✴
to accept entry. The Time
Window ? prompt appears.
PART? 12345678
HIT 0-8 X X
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...