– 107 –
1*32
RECEIVER TYPE
[0]
Enter 1 if using 4281 series receivers.
Enter 2 if using 5881 series receivers.
Important: the 4281 microprocessor must have part number N5334Vx,
where x is any number.
1*33
TOUCH-TONE W/ROTARY BACKUP [0]
Enter 1 to enable Rotary back-up dialing if communicator is not
successful on dialing using touch-tone DTMF on first attempt.
Enter 0 if this option is not desired.
1*34
COMM. SPLIT REPORT SELECTION
[0]
This field allows certain reports to be directed to either the primary or
secondary phone number.
Enter 0, 1, or 2, in accordance with the following: 0 = split reporting
disabled; 1 = alarm, alarm restore & cancel reports sent to primary telco
number, all others to secondary telco number; 2 = open/close & test
reports sent to secondary telco number and all other reports to primary; 3
= fire alarms & fire restores sent to primary telco number, all reports to
secondary. See *51 for split/dual reporting combinations.
1*42
CALL WAITING DEFEAT
[0]
Enter 1 for the panel to defeat call waiting on the first attempt (DO NOT
enable unless call waiting is being used.
Otherwise, enter 0 .
1*43
PERMANENT KEYPAD DISPLAY BACKLIGHTING
[0]
(partition-specific)
Enter 1 if it is desired that backlighting for the keypad display remain on
at all times. Enter 0 if the display should remain unlit unless a key is
pressed. The backlighting then turns off again after a period of keypad
inactivity. Note that when a key is pressed, display backlighting turns on
for all keypads in that partition.
1*44
WIRELESS KEYPAD TAMPER DETECT
[0]
Enter 1 to enable tamper detection on wireless keypad.
Enter 0 if tamper detection is not desired. If this feature is enabled, any
attempt to tamper by means of many trial entries at a wireless keypad will
be blocked by the control panel. If more than 40 key depressions are
received without a valid sequence (arm, disarm, etc.), the Control panel
will disable the wireless keypad. The inhibit is removed once a valid key
sequence is received from a wired keypad.
1*45
EXIT DELAY SOUNDING (partition-specific)
[0]
Enter 1 if beeps from the keypads during exit delay is desired. Enter 0
for no keypad sound during exit delay.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...