– 132 –
Section 23: SCHEDULING OPTIONS
This section provides the following information:
•
Main features of scheduling
•
Time Window Definitions
•
Open/Close Schedule Definitions
•
Programming in the #80 Scheduling menu mode for:
Time Windows
Open/Close Schedules
Holiday Schedules
Time Driven Events
Access Schedules
•
Programming in the #81 Temporary Scheduling mode
•
Programming in the #83 User Scheduling mode
Introduction To Scheduling
This section describes the scheduling features provided with this control panel.
UL
1.
You must program bypass and auto-arm fail reports for UL installations.
2.
Auto-disarming is not for use in UL installations.
General
•
The scheduling features of this control allow certain operations
to be automated, such as auto-arming, auto-disarming, auto-
bypassing and un-bypassing of zones, and activating relay
outputs (using 4204 modules).
•
The system uses time windows for defining open/close
schedules, holiday schedules and user defined temporary
schedules. Scheduled events are programmed by user-friendly
menu modes of programming (#80, #81 & #83 modes),
explained in detail in this section. These menus take you step
by step through the options.
Auto Arming
•
The system can automatically arm (AWAY mode) itself at the
end of a pre-determined closing (arming) time window, if the
system has not been armed manually. Auto arming can be
delayed three ways: by use of the auto arm delay, the auto arm
warning, or by manually extending the closing (arming) time
window with a keypad command. The system can also
automatically bypass any open zones when auto arming.
Auto-Arm Delay
•
Auto-arm delay provides a delay (grace period) before auto
arming. It starts at the end of the closing window. The delay is
set in 4 minute increments, up to 56 minutes in partition-specific
program field 2*05. The expiration of this delay causes the
auto-arm warning to start.
Auto-Arm •
The auto-arm warning causes the keypad sounder to warn
Warning
the user of an impending auto-arm. The warning can be set to
start 01 to 15 minutes prior to arming in partition-specific
program field 2*06. During this period the keypad will beep
every 15 seconds and display "AUTO ARM ALERT" When the
remaining time drops below 60 seconds, the keypads will begin
to beep every 5 seconds. The panel will arm at the conclusion
of the auto-arm warning period.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...