Section 12: J2 TRIGGER OUTPUTS
This section provides the following information:
•
General information about the J2 triggers
•
Setup of the J2 triggers for specific applications
General Information
The J2 connector, located in the upper righthand corner of the main PCB,
provides 1 input (labeled INPUT 1) and seven trigger outputs (labeled OUT 1 -
OUT 7) that can be used to interface to the following:
•
Remote keypad sounder
•
UL Listed keyswitch
•
5140LED Indicator Module
•
Auxiliary alarm signaling equipment such as an Ademco Long Range
Subscriber Radio
•
Event logging serial printer (via the 4100SM Interface Module)
•
PC computer used to direct wire download the panel's programming
information (via the 4100SM Interface Module)
The trigger output ratings are listed below. Note that all outputs are power-
limited.
Outputs 1, 5, 7:
LOW:
2K to ground
HIGH: 10-14 VDC @ 20 mA max
Remaining Outputs:
LOW:
1K to ground
HIGH: 10-14 VDC through 5K
The pin assignments for the J2 connector are shown in the diagram below. Use
a 4142TR 9-wire trigger cable (1 supplied) to interface with this connector. The
panel does not supervise field wiring connected to this connector.
Program fields 3*19 & 3*20 are used to select the functions of INPUT 1 and OUT
1-7 as indicated in
Figure 15.
When using J2 for LORRA, INPUT 1 (Pin 9) is supervised by Zone 973, which is
used for supervision of the LORRA XMIT OKAY signal. Assign a 24-hr. zone
response type (5 or 19) to this zone.
1
2
3
4
5
6
7
8
9
FIELD 3*19 = 0
FIELD 3*19 = 0
FIELD 3*19 = 0
FIELD 3*19 = 1
FIELD 3*20 = 0
FIELD 3*20 = 1
FIELD 3*20 = 2
(DEFAULT)
LORRA
LORRA
LORRA
XMIT OKAY
XMIT OKAY
XMIT OKAY
PRINTER DTR
KEYSWITCH
5140LED
AS SELECTED
OPEN/CLOSE
ARMED LED
AC FAIL LED
IN FIELD 3*20
REMOTE
KEYSWITCH
5140LED
AS SELECTED
CONSOLE SOUNDER
READY LED
DIALER 2 FAIL LED
IN FIELD 3*20
FIRE ALARM
FIRE ALARM
FIRE ALARM
PRINTER RXD
FIRE FIRE
FIRE
AS
SELECTED
SUPERVISORY
SUPERVISORY
SUPERVISORY
IN FIELD 3*20
BURGLARY
BURGLARY
5140LED
AS SELECTED
ALARM
ALARM
COMM FAIL LED
IN FIELD 3*20
TROUBLE TROUBLE
TROUBLE AS
SELECTED
IN FIELD 3*20
PANIC ALARM
PANIC ALARM
5140LED
AS SELECTED
DIALER 1 FAIL LED
IN FIELD 3*20
INPUT 1
GROUND
OUT 1
OUT 4
OUT 7
OUT 3
OUT 6
OUT 2
OUT 5
J2 CONNECTOR
MAKE CONNECTIONS USING 4142TR (1 SUPPLIED)
Figure 15: J2 Pin Assignments and Functions
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...