– 98 –
Section 21: DATA FIELD DESCRIPTIONS
The following is a description of all data fields provided by this control. If you
have followed earlier instructions during the installation of the various devices,
many of these fields will already have been programmed.
If you need more information about actual programming procedures, see Section
4:
THE MECHANICS OF PROGRAMMING.
*00
INSTALLER CODE
| | |
The Installer's Code is a 4-digit code reserved for installation company
use. This is the only code that can be used to enter the Program mode
from the keypad. This code cannot be used to disarm the system if not
used to arm the system. This code cannot reenter programming mode if
exited by the *98 command.
*08
TEMPORAL SIREN PULSE
[0]
If either bell is selected for pulsing (program field 3*15), this field will
determine the rhythm and rate of pulsing as follows: If enabled (1), pulse
rate will be three dings and a pause, repeated. If disabled (0), the pulse
rate will be 1 sec. on, 1 sec. off.
*09
ENTRY DELAY #1 (partition-specific)
[02] |
Entry delay defines the delay time which allows users to re-enter the
premises through a door that has been programmed as an entry delay
door and disarm the system without sounding an alarm. The system must
be disarmed within this period or an alarm will occur. Enter the entry
delay time (01-15 times 15 seconds or 00 for no delay), up to a maximum
delay of 225 seconds (entry 15 times 15 seconds), for zones assigned to
Zone Type 01.
*10
EXIT DELAY #1 (partition-specific)
[03] |
Exit delay defines the delay period that allows users to leave the
premises through a door that has been programmed as an entry/exit
delay door after arming the system without setting off the alarm. Enter
the exit delay time (01-15 times 15 seconds or 00 for no delay), up to a
maximum delay of 225 seconds, for zones assigned to Zone Type 01.
*11
ENTRY DELAY #2 (partition-specific)
[06] |
Entry Delay #2 is used for a secondary door requiring a longer delay than
those assigned to Entry Delay #1. This delay may not exceed 45
seconds for UL Commercial Burglary installations.
*12
EXIT DELAY #2 (partition-specific)
[08] |
Exit Delay #2 is used for a secondary door requiring a longer delay than
those assigned to Exit Delay #1. This delay may not exceed 60 seconds
for UL Commercial Burglary installations.
*13
BELL 1 TIMEOUT (partition-specific)
[04] |
Defines the length of time Bell Output 1 and the keypad's sounder will
sound for all audible alarms (multiply entry 01-15 by 2 minutes for actual
duration).
Must be a minimum of 16 minutes for UL Commercial Burglary
installations, and 6 minutes for UL Commercial Fire installations.
www.PDF-Zoo.com
firealarmresources.com
Summary of Contents for VISTA-100
Page 197: ... 187 Insert DIP Switch Table Board A www PDF Zoo com firealarmresources com ...
Page 198: ... 188 Insert DIP Switch Table Board B www PDF Zoo com firealarmresources com ...
Page 199: ... 189 Insert DIP Switch Table Board C www PDF Zoo com firealarmresources com ...
Page 206: ... 196 NOTES www PDF Zoo com firealarmresources com ...