– 150 –
06 OFF TIME ?
11:45 PM
Enter the OFF time in 00:01 - 11:59 format.
When the display shows the desired time, press the *
key to move to the AM/PM field. In this field, any of the
keys 0-9 may be used to toggle the AM/PM indication.
Enter 00:00 to skip.
06 Days? MTWTFSS
Hit 0-7 x x
To select the days which are to be activated, enter 1-7
(Monday = 1). An "X" will appear under that day,
indicating the output for that day is active. Entering a
day's number again will deactivate that day. Pressing 0
will toggle all days on/off.
The outputs will only be in effect for the days which have
the letter x underneath them. As the week progresses,
the selected days are reset to the inactive state, unless
the permanent option is selected (next screen prompt).
When completed, press * to continue.
06 Permanent ?
0 = NO,1 = YES 0
Selecting "Permanent" means that this schedule will be
in effect on a continuous basis. An answer of 0 means
that this schedule will be in effect for one week only.
The letter "x" under the day will then be cleared.
Press * to accept entry. The system will quit User
Scheduling mode and return to normal mode.