Refitting the cable harness - lower arm
Note
Action
xx1300000668
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
procedure and to avoid damaging the parts
during the procedure.
This will also make it easier to run the cable
harness through the inside of the robot.
1
xx1300000733
Run the upper end of the cable harness up
through the lower arm.
2
xx1300000734
Refit the axis-2 lower arm metal clamp
located on the inside of the lower arm.
Note
The screws are reached from the outside
of the lower arm.
3
Continues on next page
Product manual - IRB 6700Inv
371
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.5.5 Replacing the lower arm
Continued