Removing the cable harness - base, frame and lower arm
These procedures describes how to remove the cable harness from base, frame
and lower arm.
Preparations before removing the cable harness in the base
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1300000561
Remove the base cover.
2
xx1300000591
Disconnect connectors:
•
R1.MP
•
R1.SMB
3
xx1400000366
If used, disconnect the DressPack hoses
in the base.
4
Continues on next page