Removing the stop pin
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot
working area.
1
xx1700000356
Hold the mechanical stop pin in a firm grip.
Remove the set screw, cup point.
2
xx1700000358
Remove the stop pin.
3
Continues on next page
Product manual - IRB 6700Inv
451
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.6.4 Replacing the stop pin
Continued