Note
Action
xx1200001066
Disconnect the motor cables.
4
xx1200001067
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.
6
Removing the axis-3 motor
Note
Action
Before removing the motor, make sure that
the axis-3 gearbox is completely drained.
1
DANGER
When releasing the holding brakes of the
motor, the upper arm will be movable and
may fall down if not secured. Verify that
the upper arm is secured as previously
described, before continuing.
2
To release the brakes, connect the 24 VDC
power supply.
3
Connect to connector R2.MP3:
•
+ = pin 2
•
- = pin 5
Continues on next page
484
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.7.3 Replacing the axis-3 motor
Continued
Summary of Contents for IRB 6700I
Page 1: ...ROBOTICS Product manual IRB 6700Inv ...
Page 16: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 672: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 722: ...This page is intentionally left blank ...
Page 729: ......