Note
Action
xx1300000544
Secure the cable harness to the cable fixing
bracket with a cable tie.
Note
If DressPack is fitted, the cable fixing
bracket is replaced by the cable guide.
xx1300001973
14
Connecting the axis-3 and axis-4 motor cables
Note
Action
xx1300000738
Push the motor cables through the cable
gland opening.
1
xx1200001067
Refit the cable gland cover.
Note
Replace the gasket if damaged.
2
Continues on next page
Product manual - IRB 6700Inv
253
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.2 Refitting the cable harness
Continued