Starting the calibration procedure
Use this procedure to start the Axis Calibration routine on the FlexPendant.
Note
Action
On the
ABB
menu, tap
Calibration
.
xx1500000942
1
All mechanical units connected to the system are
shown with their calibration status.
2
Tap the mechanical unit in question.
xx1500000943
Continues on next page
Product manual - IRB 6700Inv
691
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
5 Calibration
5.4.4 Axis Calibration - Running the calibration procedure
Continued