Note
Action
xx1400000088
If used, use caution and pull out the
DressPack hoses through the protection
tube in the base.
Note
There is no need to pull out the DressPack
cables
at this point!
7
Removing the cable harness in the base
Note
Action
If equipped with DressPack, pull out the
DressPack cables through the protection
tube and place them carefully over the
balancing device.
1
xx1300000732
Pull out the robot cable harness through
the protection tube.
2
Place the cable harness over the balancing
device.
3
Lifting away the complete arm system
Note
Action
xx1700001256
Remove the cable guide in the frame by re-
moving the four attachment screws and
pulling the guide upwards.
1
Continues on next page
574
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.8.2 Replacing the axis-1 gearbox
Continued