Required spare parts
Note
Article number
Spare part
Battery includes protection
circuits. Only replace with the
specified spare part or an
ABB-approved equivalent.
See
Product manual, spare
parts - IRB 6700/IRB 6700Inv
.
Product manual, spare
parts - IRB 6790
Battery unit
Removing the battery
Use this procedure to remove the SMB battery.
Note
Action
This is done in order to facilitate
updating of the revolution counter.
Jog the robot to its calibration position.
1
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
2
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
is sensitive to ESD on page 53
3
xx1700000045
Remove the SMB battery cover by unscrewing the
attachment screws.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
4
Pull out the battery and disconnect the battery
cable.
5
Remove the SMB battery
.
Battery includes protection circuits. Only replace
with a specified spare part or with an ABB- ap-
proved equivalent.
6
Continues on next page
Product manual - IRB 6700Inv
175
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
3 Maintenance
3.4.8 Replacing the SMB battery
Continued
Summary of Contents for IRB 6700I
Page 1: ...ROBOTICS Product manual IRB 6700Inv ...
Page 16: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 672: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 722: ...This page is intentionally left blank ...
Page 729: ......