Note
Action
xx1300000544
Cut the cable tie at the cable fixing bracket.
Note
If DressPack is fitted, the cable fixing
bracket is replaced by the cable guide.
xx1300001973
Cable guide.
9
Cable fixing bracket.
xx1300000541
Remove the metal clamp on top of the arm
house.
10
Continues on next page
224
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness
Continued
Summary of Contents for IRB 6700I