Note
Action
xx1500001030
Remove the heat protection plates from the
motor with the cabling still attached to the
plate.
5
xx1500001029
Cut the cable ties that hold the cable har-
ness to the plate.
Note
Keep the heat protection plate until refitting.
Tip
If removing the plate only for replacing the
motor, the cabling does not need to be
loosened from the plate.
6
Disconnecting the axis-6 motor cables
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001080
Unscrew the attachment screws and re-
move the motor cover.
2
Continues on next page