Connecting the axis-5 motor cables
Note
Action
xx1300000738
Push the motor cables in through the cable
gland opening.
1
xx1200001016
Refit the cable gland cover by performing
the following steps:
•
Slide the cable gland cover onto the
inner screw.
•
Refit and tighten the outer screw.
•
Tighten the inner screw. Make sure
that the gasket is not damaged.
Note
Replace the gasket if damaged.
2
xx1200001015
Connect the connectors.
Connect in accordance with the markings
on the connectors.
3
Continues on next page
Product manual - IRB 6700Inv
323
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the wrist
Continued