Note
Action
xx1200001066
Connect the motor cables.
Connect in accordance with the markings
on the connectors.
3
O-ring, axis-1: 3HAC054692-002
Inspect the o-ring.
Note
Replace if damaged.
4
O-ring, axis-2: 3HAC054692-002
O-ring, axis-3: 3HAC054692-002
O-ring, axis-4: 3HAC054692-001
xx1200001070
Wipe clean o-ring and o-ring groove.
5
Refit the o-ring.
Tip
Lubricate the o-ring with some grease for
a better fitting in the groove.
6
CAUTION
When fitting the motor cover, make sure
that none of the cables inside will be dam-
aged.
7
Continues on next page