Note
Action
xx1300000834
Pull out the battery cable through the recess for
the battery.
7
xx1300000669
Secure the SMB cover with its attachment
screws.
If cabling is used for 7th axis (option), refit the
connector R2.FB7 to the SMB cover and tighten
with 6 Nm.
8
Refitting the SMB battery
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section
The unit is sensitive to ESD on page 53
1
Reconnect the battery cable.
2
xx1300000829
Place the battery in the recess.
3
Refit the battery cover.
4
Continues on next page
266
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.3 Replacing the SMB
Continued
Summary of Contents for IRB 6700I