Removing the brake release unit
Preparations before removing the brake release unit
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded space.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 53
2
xx1300000743
Remove the push button guard from the SMB cover.
The push button guard must be removed to ensure
a correct refitting of the brake release unit.
3
xx1300000742
Remove the SMB cover.
4
The battery can stay connected, to avoid the need of
synchronizing the robot.
CAUTION
If the battery stays connected, put (or hold) the SMB
cover in a safe position. The battery cable connectors
can otherwise be damaged.
5
Continues on next page
Product manual - IRB 6700Inv
269
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit
Continued