Inspecting, mechanical stops
Use this procedure to inspect the additional mechanical stops.
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working area.
1
Shown in figure
Make sure no additional stops are damaged.
2
Make sure the stops are properly attached.
3
Correct tightening torque, additional mechanical
stops:
•
Axis 1 = 60 Nm.
Article number is specified in
Required equipment on page 134
If any damage is detected, the mechanical stops must
be replaced.
Correct attachment screws:
•
M12x70 quality 12.9 Gleitmo 603 (2 pcs per
additional mechanical stop)