Disconnecting the brake release unit
Note
Action
DANGER
Make sure that all supplies for electrical power, hy-
draulic pressure, and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the unit
please read the safety information in the section
unit is sensitive to ESD on page 53
2
Take a picture or make notes of how the robot cabling
is positioned in regard to the brake release board.
3
xx1300000670
Remove the connectors X8, X9 and X10 from the
brake release board.
4
Removing the brake release unit
Note
Action
xx1300000744
Unscrew the attachment screws that secure the brake
release unit bracket.
1
Remove the bracket with the brake release unit fitted.
2
Remove the brake release unit from the bracket.
3
Continues on next page
270
Product manual - IRB 6700Inv
3HAC058254-001 Revision: L
© Copyright 2017 - 2020 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit
Continued
Summary of Contents for IRB 6700I
Page 1: ...ROBOTICS Product manual IRB 6700Inv ...
Page 16: ...This page is intentionally left blank ...
Page 40: ...This page is intentionally left blank ...
Page 182: ...This page is intentionally left blank ...
Page 672: ...This page is intentionally left blank ...
Page 704: ...This page is intentionally left blank ...
Page 720: ...This page is intentionally left blank ...
Page 722: ...This page is intentionally left blank ...
Page 729: ......