Adding UPS Support to an Existing VCX System
133
Enter
Y
(you must uppercase) to indicate there are multiple UPS
devices servicing the VCX system.
-- upsipaddr <
IP Address of the UPS
>
Enter the IP address of the first UPS. Use dotted decimal notation but
do not enter leading zeros. For example, enter 10.230.63.3,
not
010.230.063.003.
-- community <
community string of the UPS
>
Enter the SNMP community string configured on the first UPS to
enable communication between the master VCX server and the UPS.
Typically, the community string is
private
to allow Read or Write
access.
-- upsipaddr1 <
IP Address of the second UPS
>
Enter the IP address of the second UPS.
-- community1 <
community string of the second UPS
>
Enter the SNMP community string configured on the second UPS to
enable communication between the master VCX server and the UPS.
Typically, the community string is
private
to allow Read or Write
access.
-- bcharge <
UPS battery threshold charge
>
Enter UPS battery threshold charge allowed before starting a
shutdown of the VCX system. The threshold charge is expressed as a
percentage of remaining battery power. The default is 25%. The
range from 25% to 75%.
The following example shows the syntax required to initially configure a
master VCX server:
vcx-ups-setup --master Y --monitormultipleups Y
--upsipaddr 10.230.63.3 --community private
--upsipaddr1 10.230.63.4 --community1 private --bcharge 33
When this command is executed:
■
UPS monitoring is enabled on the current VCX server.
■
The server is designated the master.
■
The VCX system will be serviced by a multiple UPS devices.
■
The IP address of the first UPS is 10.230.63.3.
■
The community string the first UPS will use to communicate with the
master VCX server is private.
Summary of Contents for VCX V7000
Page 26: ...26 CHAPTER 1 VCX SYSTEM MAINTENANCE OVERVIEW ...
Page 68: ...68 CHAPTER 3 MANAGING VCX SERVERS ...
Page 78: ...78 CHAPTER 4 BACKING UP AND RESTORING A VCX CONFIGURATION ...
Page 88: ...88 CHAPTER 5 MANAGING AUTHENTICATION AND DIRECTORY SERVICE DATABASES ...
Page 100: ...100 CHAPTER 6 MANUALLY CONFIGURING MULTI MASTER REPLICATION ...
Page 140: ...140 CHAPTER 8 MANAGING UNINTERRUPTIBLE POWER SUPPLIES ...
Page 250: ...250 APPENDIX B UPGRADING VCX SERVER SOFTWARE FROM V7 1 X TO V7 1 Y ...
Page 290: ...290 APPENDIX C UPGRADING VCX SERVER SOFTWARE FROM V6 0 TO V7 0 ...
Page 328: ...328 APPENDIX D DOWNGRADING VCX SERVER SOFTWARE ...
Page 339: ...CLI Command Descriptions 339 ...