When you have multiple UPS devices, you should connect each UPS to
different mains circuits if possible.
Dual UPS System – Configuring the Master VCX Server
To enable and configure a VCX server as the master in a multiple UPS
system:
1
Log in, using the
root
account, to the VCX server you want to designate
as the master.
2
Enter the following command:
vcx-ups-setup <configuration_parameters>
You must concatenate the following
vcx-ups-setup
command
configuration parameters (responses are shown in bold):
-- master:
Y
Enter
Y
(you must uppercase) to designate this server as the master.
-- monitormultipleups:
Y
UPS
UPS
VCX Server
VCX Server
Primary IPM
Server
Secondary IPM
Server