www.dadehpardazan.ir 88594014-15
10.2 List of Parameters
10-21
10
Ap
pend
ix
Pn20E
4
Electronic Gear Ratio
(Numerator)
1 to
1073741824
1
4
After restart
Setup
Pn210
4
Electronic Gear Ratio
(Denominator)
1 to
1073741824
1
1
After restart
Setup
Pn216
2
Position Reference
Acceleration/Deceleration
Time Constant
0 to 65535
0.1 ms
0
Immediately
after the ser-
vomotor stops
Setup
Pn217
2
Average Movement Time of
Position Reference
0 to 10000
0.1 ms
0
Immediately
after the ser-
vomotor stops
Setup
Pn218
2
Reference Pulse Input
Multiplication
1 to 100
1 time
1
Immediately
Setup
Pn281
2
Encoder Output Resolution
1 to 4096
1 edge/
pitch
20
After restart
Setup
Pn282
4
Linear Scale Pitch
0 to 6553600
0.01
m
0
After restart
Setup
Pn300
2
Speed Reference Input Gain
150 to 3000
0.01V
/rated
speed
600
Immediately
Setup
Pn305
2
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immediately
Setup
Pn306
2
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immediately
Setup
Pn307
2
Speed Reference Filter Time
Constant
0 to 65535
0.01 ms
40
Immediately
Setup
Pn310
2
Vibration Detection Switch
0000 to 0002
0000
Immediately
Setup
Pn311
2
Vibration Detection
Sensibility
50 to 500
1%
100
Immediately
Tuning
Pn324
2
Mass Calculating Start Level
0 to 20000
1%
300
Immediately
Setup
Pn380
2
Internal Set Speed 1
0 to 10000
1 mm/s
10
Immediately
Setup
Pn381
2
Internal Set Speed 2
0 to 10000
1 mm/s
20
Immediately
Setup
Pn382
2
Internal Set Speed 3
0 to 10000
1 mm/s
30
Immediately
Setup
Pn383
2
JOG Speed
0 to 10000
1 mm/s
50
Immediately
Setup
Pn384
2
Vibration Detection Level
0 to 5000
1 mm/s
10
Immediately
Tuning
Pn385
2
Motor Max. Speed
1 to 100
100 mm/s
50
After restart
Setup
Pn400
2
Force Reference Input Gain
10 to100
0.1 V/
rated
force
30
Immediately
Setup
Pn401
2
Force Reference Filter Time
Constant
0 to 65535
0.01 ms
100
Immediately
Tuning
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Vibration Detection Selection
Reference
Section
0
Does not detect vibration.
1
Outputs warning (A.911) when vibration is detected.
2
Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...