www.dadehpardazan.ir 88594014-15
6 Adjustments
6.9.5 Mode Switch (P/PI Switching)
6-68
(2) Operating Examples for Different Switching Conditions
Using the Force Reference [Factory Setting]
With this setting, the speed loop is switched to P control when the value of force reference input exceeds the
force set in Pn10C. The factory setting for the force reference detection point is 200% of the rated force.
Using the Speed Reference
With this setting, the speed loop is switched to P control when the value of speed reference input exceeds the
speed set in Pn181.
Using Acceleration
With this setting, the speed loop is switched to P control when the speed reference exceeds the acceleration set
in Pn182.
Using the Position Error
With this setting, the speed loop is switched to P control when the position error exceeds the value set in
Pn10F.
This setting is effective with position control only.
Motor speed
Speed reference
Speed
+Pn10C
Force
Reference
- Pn10C
Force reference
PI Control
PI Control
0
PI
P
P
Time
Linear
Speed reference
Speed
Motor speed
Time
P Control
PI Control
Pn181
PI
Linear
Motor
speed
Speed reference
Speed
Motor acceleration
+Pn182
Acceleration
- Pn182
PI Control
PI Control
0
PI
P
P
Time
Linear
Position
error
Speed reference
Speed
Motor speed
Time
P Control
PI Control
Pn10F
PI
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...