www.dadehpardazan.ir 88594014-15
5 Operation
5.8.4 Force Limiting Using an External Force Limit and Analog Voltage Reference
5-68
(1) Input Signals
Use the following input signals to limit a force by external force limit and analog voltage reference.
Refer to
5.5.1 Basic Settings for Force Control
.
(2) Related Parameters
Set the following parameters for force limit by external force limit and analog voltage reference.
The setting unit is a percentage of the rated force.
Type
Signal Name
Connector
Pin Number
Name
Input
T-REF
CN1-9
Force reference input
SG
CN1-10
Signal ground for force reference input
Type
Signal
Name
Connector
Pin Number
Setting
Meaning
Limit Value
Input
/P-CL
CN1-45
[Factory setting]
ON
Forward external force limit ON
The smallest value of these set-
tings: the analog voltage refer-
ence limit, Pn483, or Pn404
OFF
Forward external force limit OFF Pn483
Input
/N-CL
CN1-46
[Factory setting]
ON
Reverse external force limit ON
The smallest value of these set-
tings: the analog voltage refer-
ence limit, Pn484, or Pn405
OFF
Reverse external force limit OFF
Pn484
Pn400
Force Reference Input Gain
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
Setup
10 to 100
0.1 V
30 (Rated force at 3.0
V)
Immediately
Pn483
Forward Force Limit
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
Setup
0 to 800
1%
30
Immediately
Pn484
Reverse Force Limit
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
Setup
0 to 800
1%
30
Immediately
Pn404
Forward External Force Limit
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
Setup
0 to 800
1%
100
Immediately
Pn405
Reverse External Force Limit
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
Setup
0 to 800
1%
100
Immediately
Pn415
T-REF Filter Time Constant
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 65535
0.01 ms
0
Immediately
Setup
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...