www.dadehpardazan.ir 88594014-15
10 Appendix
10.1.7 Connection to MITSUBISHI’s QD75D
Positioning Module (SERVOPACK in Position Control)
10-8
10.1.7
Connection to MITSUBISHI’s QD75D
Positioning Module
(SERVOPACK in Position Control)
The ALM signal is output for about five seconds when the control power is turned ON. Take this into consideration
when designing the power ON sequence. Also, use the ALM signal to actuate the alarm detection relay 1Ry to stop
the main circuit power supply to the SERVOPACK.
represents twisted-pair wires.
Note 1. Only the signals that are related to the SGDV SERVOPACK and the QD75D Mitsubishi Positioning Module are
shown in the diagram.
2. The main circuit power supply is a three-phase 200 VAC SERVOPACK input in the example.
3. Incorrect wiring may damage the Positioning Module or SERVOPACK. Wire all connections carefully.
4. Open the signal lines not to be used.
5. The above connection diagram shows the connections for only one axis. When using other axes, make connec-
tions to the SERVOPACK in the same way.
6. Short-circuit the normally closed (NC) input terminals that are not used at the I/O connector section of the posi-
tioning module.
7. Make the settings so that the servo can be turned ON/OFF by the Servo ON (/S-ON) signal.
8. The SERVOPACK incorporates safety functions to protect people from the hazardous operation of the movable
parts of the machines, reduce the risk, and ensure the safety of the machine in operation. Necessary circuits and
settings are required in CN8 to use these functions. If these functions are not used, use the SERVOPACK with the
enclosed safety jumper connected to CN8. For details, refer to
CN1
42
43
40
47
/S-ON
P-OT
N-OT
+24 V
SGDV SERVOPACK
L1C
L3
L2
L1
L2C
DOG
3
FLS
1
RLS
2
STOP
4
READY
11
READY COM
12
COM
6
COM
7
PULSE R+
17
PULSE R-
18
PULSE F+
15
PULSE F-
16
PG05
9
PG COM
10
CLEAR
13
CLEAR COM
14
11
SIGN
12
/SIGN
7
PULS
8
/PULS
19
PCO
20
/PCO
15
CLR
14
/CLR
31
ALM+
32
ALM-
2.2 k
Ω
1Ry
+
-
+24 V
0
24
V
+24 V
1Ry
CN1
∗
2
∗
1
CN2
W
V
U
M
Enc
Servomotor
Linear scale
Properly treat the end of
shielded wires.
Serial
converter
unit
0
24
V
I/O power supply
ON when
proximity is
detected
ON when
positioning
is cancelled
Control
power supply
Main circuit
power supply
Positioning Module
QD75D
manufactured
by Mitsubishi Electric
Corporation
47
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...