7 Utility Functions (Fn
)
7-20
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Setting values are as follows:
•
"
P.0000
"
: Write permitted (Releases write prohibited mode.) [Factory setting]
•
"
P.0001
"
: Write prohibited (Parameters become write prohibited from the next power ON.)
Step
Display after Opera-
tion
Keys
Operation
1
Press the MODE/SET Key to select the utility function.
2
Press the UP or DOWN Key to select Fn010.
3
Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.
4
Press the UP or DOWN Key to set a value:
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
5
Press the MODE/SET Key to register the value. When the
setting has been completed, "donE" flashes on the display
and the screen returns to the state shown on the left.
Note: If any value other than P.0000 or P.0001 is set,
"Error" will be displayed on the screen.
6
To enable the change in the setting, turn the power OFF and ON again.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...