www.dadehpardazan.ir 88594014-15
8 Monitor Displays (Un
)
8-2
8.1
List of Monitor Displays
The monitor displays can be used for monitoring the I/O signal status, and SERVOPACK internal status.
Refer to the following table.
For details, refer to
.
For details, refer to
.
For details, refer to
8.3 Reading 32-bit Data in Decimal Displays
For details, refer to
.
If the reference pulse input multiplication switching function is enabled, the reference pulse will be multiplied by n to
obtain the reference. This function is supported by software version 001A or later.
The monitor Un022 can be used only with SGDV-
B SERVOPACKs. For details, refer to
2 Installation
of
-V Series USER’S MANUAL, Setup, Linear Motor
(No.: SIEP S800000 44).
Parameter
No.
Description
Unit
Un000
Motor moving speed
mm/s
Un001
Speed reference
mm/s
Un002
Internal force reference (in percentage to the rated force)
%
Un003
*3
Electric angle 1 (number of linear-scale pulses from polarity
origin: decimal display)
linear scale pulse
4
Un004
Electric angle 2 (from polarity origin)
deg
Un005
*1
Input signal monitor
Un006
*2
Output signal monitor
Un007
*5
Input reference pulse speed (valid only in position control)
mm/s
Un008
*5
Position error amount (valid only in position control)
reference unit
Un009
Accumulated load ratio (in percentage to the rated force: effec-
tive force in cycle of 10 seconds)
%
Un00A
Regenerative load ratio (as a percentage of the processable
regenerative power: regenerative power consumption in cycle
of 10 seconds)
%
Un00B
Power consumed by DB resistance
(in percentage to the processable power at DB activation: dis-
played in cycle of 10 seconds)
%
Un00C
*3, *5
Input reference pulse counter
reference unit
Un00D
*3
Feedback pulse counter
linear scale pulse
4
Un010
Allowable motor maximum speed and encoder output resolu-
tion
Un011
Hall sensor signal
Un012
Total operation time
100 ms
Un013
*3
Feedback pulse counter
reference unit
Un014
Effective gain monitor (gain settings 1 = 1, gain settings 2 = 2)
Un015
Safety I/O signal monitor
Un020
Motor rated speed
mm/s
Un021
Motor maximum speed
mm/s
Un022
*6
Installation environment monitor
(Operation conditions in various environments can be moni-
tored.)
%
Un084
Linear scale pitch (Scale pitch = Un084
10
Un085
[pm])
Un085
Linear scale pitch index (Scale pitch = Un084
10
Un085
[pm])
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...