www.dadehpardazan.ir 88594014-15
10.2 List of Parameters
10-23
10
Ap
pend
ix
Pn460
2
Notch Filter Adjustment
Switch
0000 to 0101
0101
Immediately
Tuning
Pn480
2
Speed Limit during Force
Control
0 to 10000
1 mm/s
10000
Immediately
Setup
Pn481
2
Polarity Detection Speed Loop
Gain
10 to 20000
0.1 Hz
400
Immediately
Tuning
Pn482
2
Polarity Detection Speed Loop
Integral Time Constant
15 to 51200
0.01 ms
3000
Immediately
Tuning
Pn483
2
Forward Force Limit
0 to 800
1%
30
Immediately
Setup
Pn484
2
Reverse Force Limit
0 to 800
1%
30
Immediately
Setup
Pn485
2
Polarity Detection Reference
Speed
0 to 100
1 mm/s
20
Immediately
Tuning
Pn486
2
Polarity Detection Reference
Accel/Decel Time
0 to 100
1 ms
25
Immediately
Tuning
Pn487
2
Polarity Detection Constant
Speed Time
0 to 300
1 ms
0
Immediately
Tuning
Pn488
2
Polarity Detection Reference
Waiting Time
50 to 500
1 ms
100
Immediately
Tuning
Pn48E
2
Polarity Detection Range
1 to 65535
1 mm
10
Immediately
Tuning
Pn490
2
Polarity Detection Load Level
0 to 20000
1%
100
Immediately
Tuning
Pn495
2
Polarity Detection
Confirmation Force Reference
0 to 200
1%
100
Immediately
Tuning
Pn498
2
Polarity Detection Allowable
Error Range
0 to 30
1 deg
10
Immediately
Tuning
Pn506
2
Brake Reference
-
Servo OFF
Delay Time
0 to 50
10 ms
0
Immediately
Setup
Pn508
2
Waiting Time for Brake Signal
When Motor Running
10 to 100
10 ms
50
Immediately
Setup
Pn509
2
Instantaneous Power Cut Hold
time
20 to 1000
1 ms
20
Immediately
Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
Notch Filter Adjustment Selection 1
0
Does not adjust 1st step notch filter automatically using utility function.
1
Adjust 1st step notch filter automatically using utility function.
Reserved (Do not change.)
Notch Filter Adjustment Selection 2
0
Does not adjust 2nd step notch filter automatically using utility function.
1
Adjust 2nd step notch filter automatically using utility function.
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...