5.9 Absolute Linear Scales
5-71
5
Op
er
at
io
n
Turn OFF the SEN signal to turn OFF the control power supply.
For the details of the absolute data reception sequence, refer to
5.9.2 Absolute Data Reception Sequence
• Maintain the high level for at least 1.3 seconds when the SEN signal is turned OFF
and then ON, as shown in the figure below.
• SEN Signal cannot be OFF while the servomotor power is ON.
SERVOPACK control
power supply
5 seconds max.
ON
OFF
OFF
ON (Normal status)
OFF
ON
50 ms
Serial data
(Phase A)
(Phase B)
(Phase B)
Approx.
15 ms
400 ms max.
1 to 3 ms
60 ms max.
(90 ms typ.)
The servomotor will not be turned ON even if /S-ON is turned ON during this interval.
ALM signal OFF
(Alarm status)
SEN signal
PAO
PBO
Servomotor power
Undefined
Undefined
(Phase A)
OFF
OFF
OFF
OFF
*
ON
Incremental
pulses
Incremental
pulses
Initial incremental
pulses
Initial incremental
pulses
47
OFF
ON (high level)
1.3 s min.
OFF
ON
15 ms min.
SEN signal
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...