www.dadehpardazan.ir 88594014-15
7.21 EasyFFT (Fn206)
7-33
7
Utili
ty Fu
ncti
ons (Fn
)
(3) Related Parameters
The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using S while this function is being executed.
No : Parameters cannot be changed using S while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
9
After the detection completes normally, press the MODE/
SET Key. The optimum notch filter for the detected reso-
nance frequency will automatically be set. When the notch
filter is set correctly, the "donE" flashes and then the display
shown on the left appears.
When the 1st notch filter frequency is already set
(Pn408.0=1), the 2nd notch filter frequency will be auto-
matically set (Pn40C).
Press the MODE/SET Key to return to step 5.
Notes:
• If both the 1st and 2nd notch filter frequencies are already
set (Pn408 = n.
1
1), no more notch filter frequencies
can be set.
• Set Pn408.0 to 0 (disables notch filter) not to use the
notch filter frequency detected by executing the EasyFFT
function.
10
Press the DATA/SHIFT Key for approximately one second.
"Fn206" is displayed again.
11
To enable the change in the setting, turn the power OFF and ON again.
(cont’d)
Step
Display after Opera-
tion
Keys
Operation
MODE/SET
DATA/
MODE/SET
DATA/
Parameter
Name
Mid-execution
changes
Automatic
changes
Pn408
Force Related Function Switch
Yes
Yes
Pn409
1st Notch Filter Frequency
No
Yes
Pn40A
1st Notch Filter Q Value
No
No
Pn40C
2nd Notch Filter Frequency
No
Yes
Pn40D
2nd Notch Filter Q Value
No
No
Pn456
Sweep Force Reference Amplitude
No
No
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...