3 Wiring and Connection
3.1.2 Using a Standard Power Supply (Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)
3-8
(4) Power Supply Capacities and Power Losses
The following table shows the SERVOPACK’s power supply capacities and power losses.
The value in parentheses is for the JUSP-RA05-E regenerative resistor unit.
The value in parentheses is for the JUSP-RA18-E regenerative resistor unit.
Note 1. SGDV-R70F, -R90F, -2R1F, -2R8F, -R70A, -R90A, -1R6A, and -2R8A SERVOPACKs do not have built-in
regenerative resistors. Connect an external regenerative resistor if the regenerative energy exceeds the specified
value.
2. SGDV-550A and -260D SERVOPACKs do not have built-in regenerative resistors. Make sure that a regenerative
resistor unit or an external regenerative resistor is connected.
Refer to
3.6 Connecting Regenerative Resistors
for details.
3. Regenerative resistor power losses are the allowable losses. Take the following actions if this value is exceeded.
•Remove the lead or shorting bar between terminals B2 and B3 on the SERVOPACK main circuit for SGDV-
3R8A, -5R5A, -7R6A, -120A, -180A, -200A, -330A, and 400-V SERVOPACKs.
•Install an external regenerative resistor. Refer to
3.6 Connecting Regenerative Resistors
4. Both the regenerative resistor unit and the external regenerative resistor are not included.
Main
Circuit
Power
Supply
Maximum
Applicable
Servomotor
Capacity
[kW]
SERVOPACK
Model
SGDV-
Power Supply
Capacity per
SERVOPACK
[kVA]
Output
Current
[Arms]
Main
Circuit
Power
Loss
[W]
Regenerative
Resistor
Power Loss
[W]
Control
Circuit
Power
Loss [W]
Total
Power
Loss [W]
Single-
phase,
100 V
0.05
R70F
0.2
0.66
5.4
–
17
22.4
0.1
R90F
0.3
0.91
7.8
24.8
0.2
2R1F
0.7
2.1
14.4
31.4
0.4
2R8F
1.4
2.8
25.6
42.6
Three-
phase,
200 V
0.05
R70A
0.2
0.66
5.1
–
17
22.1
0.1
R90A
0.3
0.91
7.3
24.3
0.2
1R6A
0.6
1.6
13.5
30.5
0.4
2R8A
1
2.8
24.0
41.0
0.5
3R8A
1.4
3.8
20.1
8
45.1
0.75
5R5A
1.6
5.5
43.8
68.8
1.0
7R6A
2.3
7.6
53.6
78.6
1.5
120A
3.2
11.6
65.8
10
22
97.8
2.0
180A
4
18.5
111.9
16
149.9
3.0
200A
5.9
19.6
113.8
161.4
5.0
330A
7.5
32.9
263.7
36
27
326.7
7.5
550A
14.6
54.7
357.8
(350)
*1
33
390.8
Three-
phase,
400 V
0.5
1R9D
1.1
1.9
24.6
14
21
59.6
1.0
3R5D
2.3
3.5
46.1
81.1
1.5
5R4D
3.5
5.4
71.3
106.3
2.0
8R4D
4.5
8.4
77.9
28
25
130.9
3.0
120D
7.1
11.9
108.7
161.7
5.0
170D
11.7
16.5
161.1
36
24
221.1
7.5
260D
14.4
25.7
218.6
(180)
*2
27
245.6
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...