1 Outline
1.5.2 Connecting to SGDV-
A05
SERVOPACK
1-16
1.5.2
Connecting to SGDV-
A05
SERVOPACK
(1) Using a Three-phase, 200-V Power Supply
Before connecting an external regenerative resistor to the SERVOPACK, refer to
3.6 Connecting Regenerative Resis-
Regenerative
resistor*
Magnetic
contactor
Host controller
When not using the safety function,
use the SERVOPACK with the safety
function’s jumper connector
(JZSP-CVH05-E, provided as an
accessory) inserted.
When using the safety function,
insert a connection cable specifically
for the safety function.
Safety function
devices
I/O signal cable
SGDV-
A05
SERVOPACK
Power supply
Three-phase 200 VAC
Turns the servo
ON and OFF.
Install a surge
absorber.
Connection cable
for digital operator
Connection cable
for personal computer
Digital
operator
Personal
computer
R S T
Servomotor with core
Linear scale
(not included)
Connection cable
for linear scale
Serial converter unit
Connection cable for
serial converter unit
Connection cable
for hall sensor
Servomotor main
circuit cable
Noise filter
Molded-case
circuit breaker
(MCCB)
Protects the power
line by shutting the
circuit OFF when
overcurrent is
detected.
Eliminates
external noise from
the power line.
47
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...