10 Appendix
10.2.2 Parameters
10-22
Pn404
2
Forward External Force Limit
0 to 800
1%
100
Immediately
Setup
Pn405
2
Reverse External Force Limit
0 to 800
1%
100
Immediately
Setup
Pn406
2
Emergency Stop Force
0 to 800
1%
800
Immediately
Setup
Pn408
2
Force Related Function Switch
0000 to 1111
0000
Pn409
2
1st Notch Filter Frequency
50 to 5000
1 Hz
5000
Immediately
Tuning
Pn40A
2
1st Notch Filter Q Value
50 to 1000
0.01
70
Immediately
Tuning
Pn40B
2
1st Notch Filter Depth
0 to 1000
0.001
0
Immediately
Tuning
Pn40C
2
2nd Notch Filter Frequency
50 to 5000
1 Hz
5000
Immediately
Tuning
Pn40D
2
2nd Notch Filter Q Value
50 to 1000
0.01
70
Immediately
Tuning
Pn40E
2
2nd Notch Filter Depth
0 to 1000
0.001
0
Immediately
Tuning
Pn40F
2
2nd Step 2nd Force Reference
Filter Frequency
100 to 5000
1 Hz
5000
Immediately
Tuning
Pn410
2
2nd Step 2nd Force Reference
Filter Q Value
50 to 100
0.01
50
Immediately
Tuning
Pn412
2
1st Step 2nd Force Reference
Filter Time Constant
0 to 65535
0.01 ms
100
Immediately
Tuning
Pn415
2
T-REF Filter Time Constant
0 to 65535
0.01 ms
0
Immediately
Setup
Pn423
2
Reserved (Do not change.)
0000
Pn424
2
Force Limit at Main Circuit
Voltage Drop
0 to 100
1%
50
Immediately
Setup
Pn425
2
Release Time for Force Limit
at Main Circuit Voltage Drop
0 to 1000
1 ms
100
Immediately
Setup
Pn456
2
Sweep Force Reference
Amplitude
1 to 800
1%
15
Immediately
Tuning
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
1st Step Notch Filter Selection
When
Enabled
Classification
Reference
Section
0
N/A
Immediately
Setup
1
Uses 1st step notch filter for force reference.
Speed Limit Selection
When
Enabled
Classification
Reference
Section
0
Uses the smaller of the maximum motor speed and
the value of Pn480 as the speed limit value.
After restart
Setup
1
Uses the smaller of the overspeed detection speed
and the value of Pn480 as the speed limit value.
2nd Step Notch Filter Selection
When
Enabled
Classification
Reference
Section
0
N/A
Immediately
Setup
1
Uses 2nd step notch filter for force reference.
Friction Compensation Function Selection
When
Enabled
Classification
Reference
Section
0
Disables friction compensation function.
Immediately
Setup
1
Enables friction compensation function.
4th 3rd 2nd 1st
digit digit digit digit
n.
Содержание SGDV SERVOPACK
Страница 23: ...www dadehpardazan ir 88594014 15 xxii ...
Страница 53: ...www dadehpardazan ir 88594014 15 2 Panel Operator 2 10 ...
Страница 103: ...www dadehpardazan ir 88594014 15 3 Wiring and Connection 3 7 3 Connecting a Reactor for Harmonic Suppression 3 50 ...
Страница 117: ...www dadehpardazan ir 88594014 15 4 Trial Operation 4 5 4 Operator Displays during Testing without Motor 4 14 ...
Страница 203: ...www dadehpardazan ir 88594014 15 5 Operation 5 11 5 Precautions for Safety Functions 5 86 ...
Страница 275: ...www dadehpardazan ir 88594014 15 6 Adjustments 6 9 7 Position Integral 6 72 ...